All cords are fine. Replace with the exact same MFD number, printed on the capacitor. I have a Hayward Super Pump Model:C48L2N134B1 that I replaced 3 or 4 seasons ago and until now I have had no trouble out of it. Apologies for the delay. If the well recovery rate is too poor and the pump is operating at low water pressure, possibly because a tailpiece is installed to prevent air injection and pump burn up, the pump may be overheating. Pump shutoff during 24 hours of pouring rain. I cut the insulation back and found that the leg I was loosing when the pump came on was damaged. I ohm ed out the motor and it is open (infinite resistance) to ground both legs and 3.2 ohms between the 2 leads going to the motor. If the well casing is plastic then you have to connect your ground lead to the circuit ground. Also for: Xc70, V70r, Xc90, 2005 v70, 2005 v70r, 2005 xc70, 2005 xc90. I was thinking that the caps may be bad and it was pulling too much current at start up and tripping the breakers. You will need at least a new pressure control switch (notice the overheated, burned contacts not just the wires), and perhaps some new wire and most trouble, perhaps a new pump). In most cases however, a motor that is over-heating tends to be defective beyond repair, when caused by an internal short across the motor windings. Gail, good luck! There are two sealed bearings inside pool pump motors. Inspect the capacitor, at 9 oclock in the rear, for bulges, cracks or brown liquid. when the pump kicked on, I was loosing one leg and this was tripping the double pole breaker. Anything else to fiddle with or bad motor? We have no relationship with advertisers, products, or services discussed at this website. I really don't know what to do and I would love some insight from a different source than the one who has misdiagnosed, potentially damaged my property, and denied wrongdoing at every turn. Tighten cable clamp. Where do the black and white wire go on a well pump that has a regulator switch, Anon:Please see your question and my detail reply athttps://inspectapedia.com/water/Well-Pump-Wiring-Damage.php, Why would the wires in my well keep breaking, On 2019-01-17 by Ronnie Neathery Fourth, bad capacitor on the motor? (GFI 240V 20amp) If breaker still trips, replace the breaker; they go bad eventually. this pump being a 2 wire only has the pressure switch no control box my email is bodyman36@hotmail.com. Intermittently meaning it could run for days then trip, I could reset the breaker and have it trip again within a few hours, or it could run for days. Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. What are the brand and model of the new pump? Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. In some cases, it can be a clog in the skimmer line, or even a partially collapsed suction line that is to blame. In this project we are going to design a Simple Time Delay Circuit Using 555 Timer IC.This circuit consists of 2 switches one for start the delay time and other for reset. etc. If the well pump motor has been damaged Goulds notes that you will see much lower resistance, maybe in the 10,000 to 20,000 Ohms range, GREEN or safety ground connects to the circuit ground and typically to a control box ground terminal and a motor chassis ground terminal. V70 automobile pdf manual download. If we don't have a short in the circuit then unfortunately that makes us suspect a failing pump motor. Check with VOM at the pressure control switch or at the pump wiring, Check that the pump pressure control switch is trying to turn on the pump and that there is voltage at the pump wiring, Check the switch contacts for burning or wear, Check the tubing connecting the pressure switch to the pump housing for clogging, Turn off electric power to pump, see if you can move the impeller or motor - if it won't turn it is jammed or damaged, Pump motor shorted out, jammed, burned up, Fuse blows or breaker trips as soon as the pump tries to turn on. Shut off power at breaker and tighten all wire connections. Schematic diagram. Hook the black wires together using wire nuts and do the same with the white or yellow wires. Also see SINGLE PHASE PUMP SERVICE MANUAL [PDF] (2005) Goulds, ITT, Website: www.goulds.com available from the company or free as a download at InspectApedia for examples of resistance tests of well pump motors and wiring. The pump need not be completely air tight, but has to pull more water than air! I've got this thing working. 9013 Pumptrol® Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G, Catalog, Water Pump Pressure Control Switch Class 9013, Type F, G, Manual, ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS, HOME INSPECTION EDUCATION COURESES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES. Here is what I found: I was showing 238V at the cut off box at the control box. Install a valve on the water discharge line and reduce water flow to increase water pressure inside the pump itself. Wire on well pump charred. It could also be that the power cord is not rated for 15 amps, which is the likely size of the breaker for the outlet (but check the breaker amp size). I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) I went to go on vacation the last couple of days but had issues so I had to come home. See pages 24 and 25 therein for notes on how to make a resistance check of the pump wires. Knowing the context is diagnostic: is this a new indication on equipment previously installed and working properly or has the indicator always been on since installation? Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. Before ordering a new capacitor however, be sure that the shaft is not “froze-up’ with rust. Are you certain that the problem is that the pump isn't running as opposed to a running pump but a leak or piping problem? If the external wiring is ok (no short circuits) the motor is shorted internally, Use a VOM to check the voltage level at the pressure control switch, If voltage is too low, check voltage at the electrical panel and check that the proper size wiring was used for the ampacity and length of run and that there are no partial shorts or damaged wires or connectors, Check the actual electrical wiring against the motor wiring diagram or the installation manual for the equipment, Motor is too hot due to surroundings - inadequate ventilation, Install adequate ventilation, or if needed, shading, or relocate the motor/equipment to a cool location, Pump operates too long at low water pressure. I have been getting GFI breaker trips intermittently. Pump is about 5 years old without problems prior to this.What could be causing this issue?? If the pump uses 220 and only one line has power (120 or 110V) then the other line is open, and dangerous. If the next day the chlorine level is nearly zero, shock again. Replace the fitting, with lots of thread sealant, or use pool putty. Do not just insulate and turn power back on.Leave the circuit off to avoid a fire and shock hazard - sorry I know that's not exactly convenient. InspectAPedia tolerates no conflicts of interest. Inherited an old Hayward super pump that hums but doesn’t turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. BTW, I forgot to add that when the pump shuts off after running for a few seconds it won’t run again until about 20-30 seconds later, even if manually holding the pressure switch “fill” lever. You need to know the normal resistance for your specific well pump brand and model. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. This lasted for about two days, and then we had to do it again. On the electrical side, problems can occur with the electric motor, timeclock, breaker or wires. If so, shut off power and see if the motor shaft will spin. It was off this morning and I reset the breaker. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. During last stay at property during heavy usage the water would recover slowly. First of all, I have 25 amp breakers going to my 1.5 HP pump that is 160 feet down. View and Download Volvo V70 wiring diagram online. I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesn’t trip the breaker switch. I notice this as dimmed lights will dim even more. Pool putty can make a semi-permanent repair, or the fitting can be cut out and replaced. ... hello from morocco i need to use this one to auto water level control my 2hp pump wich is 50m below what do i change to become very stable and is relay 10amp enough for 2hp any help thank you very much. Normally they last longer…. Test entrance pipe fitting (threads into front of pump) for Air leakage. It looks like no one has them in Stock and if I can’t filter the pool, then it won’t be usable. I'm not sure if the system is water logged or not. Water shut off and when restarted saw a spark. If the pump sounds like it’s gargling rocks, or there is heavy vibration noise, it may be cavitating, a term that means it’s starved for water. Check the motor shaft, the impeller should turn freely by hand. Not all parts are shown on the diagrams—those parts are labeled NI, for “not illustrated”. This could be caused by incorrect voltage or from clogged or restricted pipes, valves or impeller. Once I get it going, it works fine for as long as I leave it on. our sumersable pump starts but a few minutes it trips.

Mobile Homes For Sale Killeen, Tx, Witcher 3 Keira Metz Kaer Morhen, Lg Inverter Direct Drive Washer, Royal Asia Vegetable Spring Rolls Directions, Bernese Mountain Dog Puppies Kc, Tahini Fresh Market, Renbtc Vs Wbtc, Linear Equations Pdf,